Shimadzu has launched Nexis GC-2060, its new gas chromatograph to mark the firm’s 70th birthday. The solution offers high analytical performance, reduces operational complexities for users, improves analysis efficiency through intuitive workflow support functions and decreases maintenance time.
The Nexis GC-2060 supports both routine and ad-hoc analyses through a range of workflow support functions tailored to operational needs – from automating analytical tasks to on-demand operation that analyses exactly what is needed, when it is needed.
(Source: Shimadzu)
To celebrate the 70th birthday of its gas chromatography (GC) product line, Shimadzu has announced the release of the Nexis GC-2060 gas chromatograph, the flagship model in its GC lineup. Featuring detectors that deliver world-class sensitivity, it offers high analytical performance, reduces operational complexities for users, enhances analysis efficiency through intuitive workflow support functions and decreases maintenance time, mentions the company.
GCs are widely used analytical instruments in research and development as well as quality control across fields such as chemistry, pharmaceuticals, energy, food, and environmental. In recent years, demand for gas analysis has grown significantly, driven by the development of new energy technologies and ongoing Green Transformation (GX) initiatives aimed at achieving carbon neutrality. As analytical requirements continue to evolve, there is a strong demand for easy-to-operate instruments that simultaneously reduce operational complexities while delivering maximum performance.
The Nexis GC-2060 supports both routine and ad-hoc analyses through a range of workflow support functions tailored to operational needs – from automating analytical tasks to on-demand operation that analyses exactly what is needed, when it is needed, shares the firm. Productivity is further enhanced by a sample injection port and column oven capable of rapid heating and cooling, detectors that stabilize quickly at startup, and maintenance features designed for ease of use, all of which help to maximize uptime and productivity. This year marks the 70th anniversary of Shimadzu’s development of Japan’s first gas chromatograph in 1956. Building on this long legacy of innovation, the company remains committed to advancing research and development as well as quality control across a wide range of fields through high-performance, easy-to-use products.
Features
1. High-speed trace analysis with detectors offering world-class sensitivity
The sensitivity of the flame ionization detector (FID), used for analyzing organic compounds, has been enhanced by about 20 % over previous models (minimum detection limit: 1.0 pgC/sec). The thermal conductivity detector (TCD), suitable for inorganic gases, has been improved by 25 % (minimum detection limit: 300 pg/mL). Both deliver state-of-the-art performance and offer exceptional stability, enabling rapid analysis even with frequent instrument start-ups and shutdowns. This improves energy efficiency and enhances operational safety, opines the company.
2. Improved operational efficiency through simple operations
Multiple sample injection ports have sometimes been required for different types of analyses. The newly developed sample injection port – Multi Mode Injection Port (MMI) – addresses this issue by featuring five distinct injection modes, versatility that allows a single GC to accommodate a wide range of analytical needs. For example, the system supports large-volume injection for pesticide analysis in food and environmental applications as well as split injection for biofuel evaluation in the energy sector. Its unique low-thermal-mass design reduces cooling time during maintenance from 40 minutes to just 5 minutes. In addition, with a single press of the maintenance button on the GC main unit, the system automatically controls temperature, gas flow, and other parameters, helping to minimize procedural errors. Last but not least, the instrument features an Eco Idling function that analyses usage patterns and recommends optimal instrument operating schedules based on workload. This helps to reduce operational costs related to gas and electricity consumption without compromising user convenience, adds the firm.
3. Continuously evolving expandability
While maintaining the same footprint as previous models, the GC-2060 expands the number of pretreatment units, sample injection ports, and detectors that can be installed. This enables highly flexible system configurations tailored to diverse needs, such as parallel operation with dual-line analysis using the same setup, multi-application coverage with a single GC, and high-speed analysis. In addition to conventional operation, the FID supports a cylinder-free mode that uses only hydrogen and oxygen generated from pure water. This reduces barriers to GC adoption by minimizing capital investment in cylinder-related equipment and lowering management workload, thereby reducing operational costs, concludes the company.
Date: 08.12.2025
Naturally, we always handle your personal data responsibly. Any personal data we receive from you is processed in accordance with applicable data protection legislation. For detailed information please see our privacy policy.
Consent to the use of data for promotional purposes
I hereby consent to Vogel Communications Group GmbH & Co. KG, Max-Planck-Str. 7-9, 97082 Würzburg including any affiliated companies according to §§ 15 et seq. AktG (hereafter: Vogel Communications Group) using my e-mail address to send editorial newsletters. A list of all affiliated companies can be found here
Newsletter content may include all products and services of any companies mentioned above, including for example specialist journals and books, events and fairs as well as event-related products and services, print and digital media offers and services such as additional (editorial) newsletters, raffles, lead campaigns, market research both online and offline, specialist webportals and e-learning offers. In case my personal telephone number has also been collected, it may be used for offers of aforementioned products, for services of the companies mentioned above, and market research purposes.
Additionally, my consent also includes the processing of my email address and telephone number for data matching for marketing purposes with select advertising partners such as LinkedIn, Google, and Meta. For this, Vogel Communications Group may transmit said data in hashed form to the advertising partners who then use said data to determine whether I am also a member of the mentioned advertising partner portals. Vogel Communications Group uses this feature for the purposes of re-targeting (up-selling, cross-selling, and customer loyalty), generating so-called look-alike audiences for acquisition of new customers, and as basis for exclusion for on-going advertising campaigns. Further information can be found in section “data matching for marketing purposes”.
In case I access protected data on Internet portals of Vogel Communications Group including any affiliated companies according to §§ 15 et seq. AktG, I need to provide further data in order to register for the access to such content. In return for this free access to editorial content, my data may be used in accordance with this consent for the purposes stated here. This does not apply to data matching for marketing purposes.
Right of revocation
I understand that I can revoke my consent at will. My revocation does not change the lawfulness of data processing that was conducted based on my consent leading up to my revocation. One option to declare my revocation is to use the contact form found at https://contact.vogel.de. In case I no longer wish to receive certain newsletters, I have subscribed to, I can also click on the unsubscribe link included at the end of a newsletter. Further information regarding my right of revocation and the implementation of it as well as the consequences of my revocation can be found in the data protection declaration, section editorial newsletter.